acBoardTrapGlobalsName (1)
|
Alarm or event number. The number value is obtained from the last digit(s) of the OID of the sent trap, and then subtracted by 1. For example, for the trap acBoardEthernetLinkAlarm, which has an OID of 1.3.6.1.4.1.5003.9.10.1.21.2.0.10, the value of the varbind is 9 (i.e., 10 – 1).
The value is an integer from 0 to 1000.
|
acBoardTrapGlobalsTextualDescription (2)
|
Description of the reported issue.
The value is an octet string of up to 200 characters.
|
acBoardTrapGlobalsSource (3)
|
The source of the issue. For example, Trunk#1 or Entity1#x.
The value is an octet string of up to 100 characters.
|
acBoardTrapGlobalsSeverity (4)
|
Active alarm severity on the device:
|
AcBoardTrapGlobalsUniqID (5)
|
Consecutive number count of trap since device was powered on. The number is managed separately for alarms and events. For example, you may have an alarm whose value is 1 and an event whose value is 1.
The value is an integer from 0 to 32000.
|
acBoardTrapGlobalsType (6)
|
|
■
|
qualityOfServiceAlarm(2) |
|
■
|
processingErrorAlarm(3) |
|
■
|
operationalViolation(7) |
|
■
|
securityServiceOrMechanismViolation(9) |
|
■
|
timeDomainViolation(10) |
|
acBoardTrapGlobalsProbableCause (7)
|
|
■
|
applicationSubsystemFailure(2) |
|
■
|
callEstablishmentError(4) |
|
■
|
communicationsProtocolError(5) |
|
■
|
communicationsSubsystemFailure(6) |
|
■
|
configurationOrCustomizationError(7) |
|
■
|
cpuCyclesLimitExceeded(10) |
|
■
|
dataSetOrModemError(11) |
|
■
|
dteDceInterfaceError(13) |
|
■
|
equipmentMalfunction(15) |
|
■
|
heatingVentCoolingSystemProblem(21) |
|
■
|
humidityUnacceptable(22) |
|
■
|
inputOutputDeviceError(23) |
|
■
|
localNodeTransmissionError(27) |
|
■
|
materialSupplyExhausted(30) |
|
■
|
performanceDegraded(34) |
|
■
|
pressureUnacceptable(36) |
|
■
|
remoteNodeTransmissionError(42) |
|
■
|
resourceAtOrNearingCapacity(43) |
|
■
|
responseTimeExecessive(44) |
|
■
|
retransmissionRateExcessive(45) |
|
■
|
softwareProgramAbnormallyTerminated(47) |
|
■
|
softwareProgramError(48) |
|
■
|
storageCapacityProblem(49) |
|
■
|
temperatureUnacceptable(50) |
|
■
|
underlyingResourceUnavailable(56) |
|
■
|
authenticationFailure(58) |
|
■
|
breachOfConfidentiality(59) |
|
■
|
duplicateInformation(63) |
|
■
|
informationModificationDetected(65) |
|
■
|
informationOutOfSequence(66) |
|
■
|
nonRepudiationFailure(69) |
|
■
|
unauthorizedAccessAttempt(73) |
|
■
|
unexpectedInformation(74) |
|
acBoardTrapGlobalsAdditionalInfo1 (8)
|
Provides additional information regarding the reported trap.
The value is an octet string of up to 100 characters.
|
acBoardTrapGlobalsAdditionalInfo2 (9)
|
Provides additional information regarding the reported trap.
The value is an octet string of up to 100 characters.
|
acBoardTrapGlobalsAdditionalInfo3 (10)
|
Provides additional information regarding the reported trap.
The value is an octet string of up to 100 characters.
|
acBoardTrapGlobalsDateAndTime (11)
|
Date and time the trap was sent.
|
acBoardTrapGlobalsSystemSeverity (12)
|
The highest alarm severity sent by the device when the trap was sent:
|
acBoardTrapGlobalsDeviceName (13)
|
Name of the device.
The value is an octet string of up to 100 characters.
Note: The device sends an empty string "\0". AudioCodes OVOC provides the proper string value when it sends it northbound.
|
acBoardTrapGlobalsDeviceInfo (14)
|
Device information.
The value is an octet string of up to 100 characters.
Note: The device sends an empty string "\0". AudioCodes OVOC provides the proper string value when it sends it northbound.
|
acBoardTrapGlobalsDeviceDescription (15)
|
Device description.
The value is an octet string of up to 100 characters.
Note: The device sends an empty string "\0". AudioCodes OVOC provides the proper string value when it sends it northbound.
|
acBoardTrapGlobalsSystemSerialNumber (16)
|
The Serial Number of the device that sent the trap.
The value is an octet string of up to 255 characters.
|